Serial number
Testing items
technical requirement
one
Radiation emission
According to GB 9254-2008, Class A;
two
Conducted Emissions
According to GB 9254-2008, Class A;
three
electrostatic discharge
According to GB/T 17618-2015, at least 4 points should be selected for electrostatic discharge, with 100 positive and 100 negative electrodes, 4kV contact discharge, and 8kV air discharge;
four
Electric fast transient pulse group
According to GB/T 17626.4-2008
Signal terminal: 0.5kV
DC power terminal: 0.5kV
AC power terminal: 1kV
five
Conducted immunity test
According to GB/T 17626.6-2008
0.15MHz-80MHz,80%AM(1kHz),3V
six
Radiation immunity test
According to IEC61000-4-3:2006
80MHz-1GHz,80%AM(1kHz),3V/m
seven
Power frequency magnetic field
According to GB/T 17626.8-2006, 50Hz, 1A/m;
eight
surge
According to GB/T 17626.5-2008
Signal terminal: 10/700us, 1kV
DC power terminal: 1.2/50us, 0.5kV
AC power terminal: 1.2/50us,
1kV line, 2kV line to ground;
nine
Voltage dips and short interruptions
According to GB/T 17626.11-2008.
Copyright: Dongguan Zhongcewei Testing Technology Service Co., Ltd